{"id":742,"date":"2024-03-22T16:08:20","date_gmt":"2024-03-22T15:08:20","guid":{"rendered":"https:\/\/sensorarrays.com.pl\/?p=742"},"modified":"2025-05-20T14:13:45","modified_gmt":"2025-05-20T12:13:45","slug":"elzbietas-publication-featured-on-a-cover-of-acs-omega","status":"publish","type":"post","link":"https:\/\/sensorarrays.com.pl\/?p=742","title":{"rendered":"El\u017cbieta&#8217;s publication featured on a cover of ACS Omega"},"content":{"rendered":"\n<p>El\u017cbieta&#8217;s publication &#8220;<a href=\"https:\/\/pubs.acs.org\/doi\/10.1021\/acsomega.3c07660\">Methods of Protection of Electrochemical Sensors against Biofouling in Cell Culture Applications<\/a>&#8221; was recently accepted in ACS Omega. The article concerns various methods of antifouling coating for electrochemical sensors, especially applied to monitor vital culture parameters in cell cultures. The publication was featured on the main cover of the journal. <\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>The work was started by Emilia&#8217;s master&#8217;s student \u2013 Zuzia, who performed many experiments with different antifouling layers, including porous materials, permselective membranes, hydrogels, silicate sol-gels, and proteins. They were tested against a cell culture medium for three weeks. For the evaluation, a redox mediator was used, which was adsorbed on the carbon electrode surface, allowing for testing of not only the protective effect of the antifouling modification but also its impact on the catalyst itself.<br>El\u017cbieta continued it and studied the impact of selected materials (TMOS, PLLA, PLL\u2212PEG) in HeLa cell culture. We noticed that, as expected, the first hours of incubation in cell culture were crucial for the performance of the electrodes. Although significantly reduced, during an experiment lasting three weeks, signals could be maintained for prolonged incubation in a cell culture medium. They did not influence the performance of the tested catalyst.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"770\" height=\"1024\" src=\"https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/ao3c07660_front_cover_hires-770x1024.jpg\" alt=\"\" class=\"wp-image-744\" srcset=\"https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/ao3c07660_front_cover_hires-770x1024.jpg 770w, https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/ao3c07660_front_cover_hires-226x300.jpg 226w, https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/ao3c07660_front_cover_hires-768x1021.jpg 768w, https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/ao3c07660_front_cover_hires-1155x1536.jpg 1155w, https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/ao3c07660_front_cover_hires-1540x2048.jpg 1540w, https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/ao3c07660_front_cover_hires-300x399.jpg 300w, https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/ao3c07660_front_cover_hires-850x1130.jpg 850w, https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/ao3c07660_front_cover_hires-scaled.jpg 1925w\" sizes=\"auto, (max-width: 770px) 100vw, 770px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><a href=\"https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/Fig5.jpg\"><img loading=\"lazy\" decoding=\"async\" width=\"850\" height=\"643\" src=\"https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/Fig5.jpg\" alt=\"\" class=\"wp-image-745\" srcset=\"https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/Fig5.jpg 850w, https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/Fig5-300x227.jpg 300w, https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/Fig5-768x581.jpg 768w\" sizes=\"auto, (max-width: 850px) 100vw, 850px\" \/><\/a><figcaption class=\"wp-element-caption\"><em>Measurement setup for prolonged experiments in cell culture conditions, working electrode glued in the side of the Petri dish.<\/em><\/figcaption><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/image-2.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"374\" src=\"https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/image-2-1024x374.png\" alt=\"\" class=\"wp-image-751\" srcset=\"https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/image-2-1024x374.png 1024w, https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/image-2-300x110.png 300w, https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/image-2-768x281.png 768w, https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/image-2-1536x562.png 1536w, https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/image-2-850x311.png 850w, https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/image-2.png 1909w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\"><em>Redox mediator stably adsorbed on the electrode when cycled in buffer solution (left) and lossing activity when in cell culture medium (right)<\/em><\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large\"><a href=\"https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/image-1.png\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"313\" src=\"https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/image-1-1024x313.png\" alt=\"\" class=\"wp-image-749\" srcset=\"https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/image-1-1024x313.png 1024w, https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/image-1-300x92.png 300w, https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/image-1-768x235.png 768w, https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/image-1-850x260.png 850w, https:\/\/sensorarrays.com.pl\/wp-content\/uploads\/2024\/03\/image-1.png 1169w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption class=\"wp-element-caption\"><em>Effect of different coatings on the retention of the signal during prolonged measurements<\/em><\/figcaption><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p>We successfully achieved six weeks of protection for the sensors provided by the Tetramethoxysilane (TMOS) layer silicate matrix. This type of protective layer will allow electrochemical sensors to make long-term measurements in real-time in-vitro analysis. Therefore, we could monitor crucial parameters in the cell culture environment. Glucose, oxygen, or lactate, the consumption rate, provides information on cell viability and can be translated to the toxicity tests of new drugs.<\/p>\n\n\n\n<p><em>Findings from the NCBR LIDER\/38\/0138\/L-9\/17\/NCBR\/2018 project<\/em>.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>El\u017cbieta&#8217;s publication &#8220;Methods of Protection of Electrochemical Sensors against Biofouling in Cell Culture Applications&#8221; was recently accepted in ACS Omega. The article concerns various methods of antifouling coating for electrochemical sensors, especially applied to monitor vital culture parameters in cell cultures. The publication was featured on the main cover of the journal. The work was&#8230;<\/p>\n","protected":false},"author":1,"featured_media":743,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[3,26],"tags":[],"class_list":["post-742","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general-news","category-publications"],"_links":{"self":[{"href":"https:\/\/sensorarrays.com.pl\/index.php?rest_route=\/wp\/v2\/posts\/742","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/sensorarrays.com.pl\/index.php?rest_route=\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/sensorarrays.com.pl\/index.php?rest_route=\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/sensorarrays.com.pl\/index.php?rest_route=\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/sensorarrays.com.pl\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=742"}],"version-history":[{"count":2,"href":"https:\/\/sensorarrays.com.pl\/index.php?rest_route=\/wp\/v2\/posts\/742\/revisions"}],"predecessor-version":[{"id":1015,"href":"https:\/\/sensorarrays.com.pl\/index.php?rest_route=\/wp\/v2\/posts\/742\/revisions\/1015"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/sensorarrays.com.pl\/index.php?rest_route=\/wp\/v2\/media\/743"}],"wp:attachment":[{"href":"https:\/\/sensorarrays.com.pl\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=742"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/sensorarrays.com.pl\/index.php?rest_route=%2Fwp%2Fv2%2Fcategories&post=742"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/sensorarrays.com.pl\/index.php?rest_route=%2Fwp%2Fv2%2Ftags&post=742"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}